Mail*Link(r) SMTP               FWD>Operating Temperatures of FR-4 material

Bob,

I didn't receive all of your message, but it seems your customer wants to run
some printed board assemblies or printed board material at lower than ambient
in the 200-230 degree K range. 

FR-4 and most other epoxy and polyimide based, glass reinforced, printed board
resin systems have been operated at low operating temperatures with little or
no problems.  Generally no problems in the 200 degrees K range. When you go
cryogenic (a few degrees K) though, one thing to be careful about is
mechanical flex -- 

Ralph Hersey
Lawrence Livermore National Laboratory
email:  [log in to unmask]

--------------------------------------
Date: 4/15/96 6:27 PM
From: Bob Spaniol
material. While it seems clear that the upper limit would be below the 
Tg of the laminate, how far below. And what would be considered the 
lower operating temperature. My customer wanted to know if the board 
would still function at -40 degrees C. I have know idea of the end use 
of the product. Thanks in advance!!!


------------------ RFC822 Header Follows ------------------
Received: by quickmail.llnl.gov with SMTP;15 Apr 1996 18:26:35 -0700
Received: from ipc.org by simon.ipc.org via SMTP (940816.SGI.8.6.9/940406.SGI)
	 id UAA24224; Mon, 15 Apr 1996 20:16:59 -0700
Resent-Date: Mon, 15 Apr 1996 20:16:59 -0700
Received: by ipc.org (Smail3.1.28.1 #2)
	id m0u8y5v-00009LC; Mon, 15 Apr 96 18:54 CDT
Resent-Sender: [log in to unmask]
Old-Return-Path: <[log in to unmask]>
Date: Mon, 15 Apr 1996 16:55:28 -0700
Message-Id: <[log in to unmask]>
From: [log in to unmask] (Bob Spaniol )
Subject: Operating Temperatures of FR-4 material
To:
[log in to unmask]
Resent-Message-ID: <"GQpO82.0.w_K.L6kSn"@ipc>
Resent-From: [log in to unmask]
X-Mailing-List: <[log in to unmask]> archive/latest/3456
X-Loop: [log in to unmask]
Precedence: list
Resent-Sender: [log in to unmask]





ATOM RSS1 RSS2