Good Morning All,
In a message dated 96-05-09 16:17:13 EDT, Lyn Lynch wrote:
> Look at the QPL for MIL-C-46058. This won't give you performance
> results, but it will tell you which coatings have passed the
> performance requirements sections of the specification. Part of 46058
> requires humidity exposure testing per MIL STD 810. I believe this
> testing is done with the power off.
The testing in MIL-I-46058 is done per MIL-STD-202, method 106, which is a
cyclical temperature humidity profile (25C to 65C, 90% RH, twice per day).
During all times when measurements are not being made, there is a polarizing
voltage of 100 volts DC applied. Measurements are made at 500 volts DC.
>
> As far as powered-up, high moisture environmental test results, I
> suspect that you would need to test your specific design for
> performance.
I agree, but the question become how to test. We deal with a number of
customers who have their own burn-in tests under various accelerating
conditions. Some do high temp, high humidity, some cyclical, some freezing.
It all depends on what will best find your infant mortality cases.
Doug Pauls
CSL
|
|
|