TECHNET Archives

May 2007

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Victor G. Hernandez" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Wed, 23 May 2007 16:17:26 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (90 lines)
I would like to view this presentation/report.

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Hfjord
Sent: Wednesday, May 23, 2007 3:16 PM
To: [log in to unmask]
Subject: [TN] SV: [TN] SV: [TN] Definition of Eutectic Solder

Richard, George, Werner etc chief gnus,

Want a very advanced article on the theme SAC, IMC, Phosphorous rich Ni,
diffusion rate, solidifying, wetting, ENIG, crystallographic pictures,
SEM pictures, etched cross sections, X-ray investigations,
microprobing...more than 30 pages?

I made a consulting job (metallurgists, need assistance) and had a two
hours presentation of my job. Both companies were satisfied, much thanks
to advice from you, but also thanks to my collegue, who is from Beijing.
He gave me a report that lifted my eyes. I've never seen SAC/ENIG cross
section presentations like that. Not even from China Lake. Can send
offline if you are not too many. Please, be aware this is not a
popularised kind of presentation, but at a advanced metallographic
level. You may have it already...don't know, but the report is fresh.

Inge

-----Ursprungligt meddelande-----
Från: TechNet [mailto:[log in to unmask]] För Werner Engelmaier
Skickat: den 23 maj 2007 20:44
Till: [log in to unmask]
Ämne: Re: [TN] SV: [TN] Definition of Eutectic Solder

Hi Richard,
If you try to solder at or just above the Solidus temperature, you need
a 
long time to get wetting [it takes thermal energy to dissolve the base
metal into 
Sn], and you may not get good wetting art all. That is why I recommend 
Liquidus+20C for reflow soldering to Cu, and Liquidus+35C for reflow
soldering to 
Ni. This time above 183 recommendation of 60 to 90 sec is wrong.



Werner



**************************************
 See what's free at http://www.aol.com.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 15.0
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2