Subject: | |
From: | |
Date: | Mon, 29 Jul 96 08:39:31 cst |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi David:
Could you be getting a turbulent flow/disruption in the Nordson
nozzle? What about a contaminate on the PWA that is reacting with the
postcoat to form bubbles?
Dave Hillman
Rockwell Collins
[log in to unmask]
______________________________ Reply Separator _________________________________
Subject: Bubbles in Conformal Coating
Author: [log in to unmask] at ccmgw1
Date: 7/26/96 11:52 AM
Has anyone ever experienced a problem with bubbles in conformal
coating when using an acrylic coating (CONAP 1171) applied with a
Nordson Select Coat system? The bubbles appear instantly as the
coating is applied. The result is a non-conforming defect per
IPC-A-610 section 7.1.2. Thank you.
David Bruni
Manufacturing Engineer
MSA
Instrument Division
(412) 776-8848
***************************************************************************