TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Date:
Tue, 11 Jun 1996 11:35:26 +1000 (EST)
Content-Type:
text/plain
Parts/Attachments:
text/plain (18 lines)
Can anyone give me any idea as to how far apart I need to put tracks to get
1500V transient isolation.  These tracks are on the same layer. Using FR-4.
The transients are 100 to 1000 uS.  Does duration actually matter?
Is there a particular standard I should be looking at?
Are there any coatings one can apply to increase "breakdown strength" & hence
get the tracks closer?  How 'bout for inner layers?
 

-- 
Regards,                                         JNA Telecommunications Limited
                                  ___  _____     16 Smith Street
Dom Bragge    (VK2YAK)        __ / / |/ / _ |    Chatswood NSW 2067
PWB Designer, (R&Ddiv)       / // /    / __ |    AUSTRALIA
Tel: (+61 2) 9935 5792       \___/_/|_/_/ |_|
Fax: (+61 2)  417 3862                           http://www.jna.com.au