Subject: | |
From: | |
Date: | Tue, 2 Apr 1996 08:54:22 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
We have experienced minor wrinkling on a Dynachem Cut Sheet Laminator when the exit temperature rose above 50 deg C. We lowered the temperature below 50 C and the problem went away. Other than that, we have not seen any other problems with HG.
------------------------------------------------------------------------------------------------
Ed Wright - Tech. Service OS-TECH & PCB Supplies
Oliver Sales Company Phone: (214) 231-1522
13445 Floyd Circle Fax: (214) 644-3585
Dallas, Texas 75243-1595 E-mail: [log in to unmask]
------------------------------------------------------------------------------------------------
----------
From: [log in to unmask][SMTP:[log in to unmask]]
Sent: Monday, April 01, 1996 12:25 PM
To: [log in to unmask]
Subject: Dynachem Film Problems
Has anyone experienced problems with Dynachem HG film in the past 2-3 months? Particularly wrinkling during lamination or tenting issues. We have checked our Dynachem and DuPont Hot Roll Laminators and they appear OK. I understand that Dynachem changed the thickness of Mylar and it seems to come off too easily.
Any comments would be appreciated.