Although I am not from a captive assembly house, I would be glad to work
with you off-line to develop a more effective screening process. The
process that you are using now does not seem to provide much thermal
stress, and is probably not very effective in weeding out problems.
>Our company is currently evaluating the use of Burn-In or Environmental
>Stress Screening our assemblies. We are a captive house providing board
>assemblies for the process control industry.
>
>Our current ESS cycle is as follows:
>
> Assemblies are elevated to 70°C in 5°C increments per minute.
>
> Then they are dropped to 0°C
>
> The cycle is repeated 12 times.
>
> Power is applied to the assemblies in 5 minute increments, 5 min.
>on
> then 5 min. off.
>
>My questions are:
>
> Do other capitive assembly houses use a similisr test ?
>
> Do contract assembly houses use a similiar test ?
>
> If so, What resuts are expected and obtained ?
>
> Are the tests performed based on some internal or external
>
> requirements ?
>
> Are the results utilized for further actions ?
>
> If so, What actions ?
>
>Your help and feed back is greatly appreciated.
>
>Rich Ackerson
>Sr. Ind. Eng.
>Elsag Bailey Electronics
>[log in to unmask]
>
>***************************************************************************
>* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
>***************************************************************************
>* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
>* with <subject: subscribe/unsubscribe> and no text in the body. *
>***************************************************************************
>* If you are having a problem with the IPC TechNet forum please contact *
>* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
>***************************************************************************
Bill Marsh
Phone: 415-604-6979
e-mail: [log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************