Subject: | |
From: | |
Date: | Tue, 17 Jun 1997 08:54:49 +0300 (IDT) |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
IPC par. 3.5.4.4.b define classes of dewetting.
The questin is if the percentage is related to each unit of soldering (i.e.
5% of each soldering pad) or the 5% is a total of the dewetted solder area.
Similar definition is also in ANSI/J-STD-003 par. 4.2.4.5.2 - Accept/Reject
Critirion. "A minimum of 95% of each of the surface being tested..." refer
to each individual inspected pad or the total pads area being inspected?
In the first case 100% of the pads will be soldered, in the second case 5%
of the pads might have soldering problems.
What is your interpretation?
Hillel Dzigan - Quality Manager
Eltek Ltd.
Phone +972-3-939-5022, Fax +972-3-930-9581
P.O. Box 159, Petach-Tikva 49101, ISRAEL
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|