     (I lost the thread).

     Remember too, that using a cross for a ground connection (thermals)
     causes inductances to ground, albeit small (few nH).  However, in
     broadband applications, e.g. 5 - 860 MHz, this may be unacceptable.

     I agree.  Robust RF and manufacturability mix like oil and water.

     I know.  I continue to try to mix them.

     Let me know what works out.

     Regards,

     John R. Kretsch, P.E.
     Supervisor, Design Assurance
     ADC Broadband Communications

################################################################