Nora, et al:

> IPC-SM-786A gives general information on plastic parts.  JEDEC A-112A 
> gives moisture sensitivity classification requirement.  EIA-583 gives 
> packaging material requirement.  EIA/JEP 113-A gives symbols and label 
> requirement, where you can find storage requirement and time requirement. 
>  MIL-D-3464D gives desiccant requirement.  MIL-I-8835A gives humidity 
> indicator card requriement.  JESD22-A113-A gives preconditioning flow 
> requirement.

The above is true, however, speaking only on behalf of the IPC spec, 
IPC-SM-786A also has all the other items (classification, symbols, 
labels, humidity card, preconditioning flow, desiccant) in it as well.

Mike Buetow
IPC Technical Staff
2215 Sanders Road
Northbrook, IL 60062
P: 847-509-9700, ext. 335
F: 847-509-9798
[log in to unmask]