Subject: | |
From: | |
Reply To: | |
Date: | Tue, 1 Aug 2000 16:43:50 +0100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi everyone,
I have a question regarding static damage (or not) to bi-polar devices.
At present within one of our sites we hand assemble pcb's using no form of
static protection, I am told by the design authority that because the only
active device fitted is bi-polar, no protection is required - the device in
question is a Nat. Semicon. LM158AH/883 low power dual op-amp in a TO-5
package. I feel that precautions should still be taken, can anyone offer
some advice?
Regards,
Pat Diamond
Weston Aerospace
##############################################################
TechNet Mail List provided as a free service by IPC using LISTSERV 1.8c
##############################################################
To subscribe/unsubscribe, send a message to [log in to unmask] with following text in
the body:
To subscribe: SUBSCRIBE TECHNET <your full name>
To unsubscribe: SIGNOFF TECHNET
##############################################################
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information.
If you need assistance - contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
##############################################################
|
|
|