TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
David Arivett <[log in to unmask]>
Date:
Thu, 22 Aug 1996 13:51:32 -0500 (CDT)
Content-Type:
text/plain
Parts/Attachments:
text/plain (24 lines)


We are a printed circuit board manufacturer and have been testing gold
porosity on contact fingers with the Electrographic Paper test per Bellcore
TR-NWT-0000078, paragraph 14.2.2.1 for many years. Our supplier for the
electrographic paper (Dyntronix) is going to discontinue selling the Nioxime
paper because the manufacturer is not going to make it anymore. Is anyone
else using this test method? If so, is there another supplier of this paper?
If not, what method are you using? Bellcore also allows electrographic gel
or a corrosive gas test (typically nitric vapor). Any info is appreciated.

Thanks,
David Arivett
Cuplex Inc.

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************



ATOM RSS1 RSS2