Hi Ken,
Unfortunately, "120 ppm/c (ambient to 288C)" is technical nonsense, because
it combine 2 regions with different CTEs. All you can conclude from this is
that from ambient [25C] to 288C [delta-T= 263C] there is a thermal expansion of
120e-6 x 100 x 263 = 3.16%
Regards,
Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL 32174 USA
Phone: 386-437-8747, Fax: 386-437-8737, Cell: 386-316-5904
E-mail: [log in to unmask], Website: www.engelmaier.com