Hmmmmmmmmmmm I guess that would depend....

If the XRAY device plugs into the wall at 120, 240 or 440 and generates
the high voltage internally, I do not believe it is exempt.

If it were then so would every TV set which I believe generates high
voltage at up to 25 KV for the tube connections.

I believe that voltage regulation is meant to apply to the input voltage
not the internally generated voltages.

John

-----Original Message-----
From: Leadfree [mailto:[log in to unmask]] On Behalf Of Dane Conklin
Sent: Thursday, December 01, 2005 11:33 AM
To: [log in to unmask]
Subject: Re: [LF] Lead Shielding in Subject EEE

Jerome,
As others have hinted, RoHS Article 3(a) states that a device operating
at
or above 1000vac or 1500vdc is outside the scope of RoHS. Your x-ray
generating device is most certainly operating above 1500vdc. Being
outside
of scope is arguable "better" than an exemption because it implies there
will be no 4-year review cycle.
Dane

------------------------------------------------------------------------
-------Leadfee Mail List provided as a service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks
send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
------------------------------------------------------------------------
-------

-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-------------------------------------------------------------------------------

ATOM RSS1 RSS2