LEADFREE Archives

August 2005

Leadfree@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Brian Ellis <[log in to unmask]>
Reply To:
(Leadfree Electronics Assembly Forum)
Date:
Fri, 19 Aug 2005 18:01:24 +0300
Content-Type:
text/plain
Parts/Attachments:
text/plain (81 lines)
Can't see that that patent can be made to stick. There is more than
enough prior art for circular pads of any size. It is sufficient to
state that the reason for the pretended "infringement" is that "we have
always done it that way, and the reason is nothing to do with the
lead-free or any other solder alloy". The claim states "tin-zinc based
solder, tin-silver based solder or tin copper based solder": Note the
"based". The text of the specification clearly mentions ternary and
higher alloys, including 2 SAC ones. It is therefore not likely to help
citing a ternary one.

Brian

David Greig wrote:
> US patent 6617529 might make life a little difficult. NIPPON ELECTRIC also have a Japan patent, but I can't find a Europe
> equivalent.
> You may want to try <http://v3.espacenet.com/textdoc?DB=EPODOC&IDX=US2002074164&F=0&QPN=US2002074164> for a peak.
>
> Looks like square or non circular pads are going to be the thing. Or a circular pad extended to any distance from the hole and
> with one or more blind or thru vias any place within the circumference.
>
> Or perhaps solder with some lead content? What's the legal interpretation of "lead free"?
>
> Best Regards
>
> David Greig
> ______________________________
> GigaDyne Ltd
> http://www.gigadyne.co.uk
> ______________________________
>
> -----Original Message-----
> From: Leadfree [mailto:[log in to unmask]] On Behalf Of Colin Weber
> Sent: 19 August 2005 03:12
> To: [log in to unmask]
> Subject: [LF] Design of THT PAD Size
>
> Hi Folks,
>
> Can someone please point me in the right direction with respect to design guidelines for through hole device footprints to be
> wave soldered in lead-free manufacturing?
>
> I have heard that pads for THT device leads must be 30% larger.
> However, I don't know what IPC standard this figure or advice originates from and whether it refers to area, annulus, etc?
>
>
>
> Regards,
>
> Colin Weber
>
> -------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC
> using LISTSERV 1.8d To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field):
> SIGNOFF Leadfree To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL) Search
> previous postings at: http://listserv.ipc.org/archives Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -------------------------------------------------------------------------------
> --
> Virus scanned by Lumison.
>
> -------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Leadfree
> To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
> Search previous postings at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> -------------------------------------------------------------------------------
>

--
______________________________________________
Please note new e-mail address [log in to unmask]

-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-------------------------------------------------------------------------------

ATOM RSS1 RSS2