Look at the Td spec on the laminate data sheet............ go look at

the laminate mfrs websites - Isola - Polyclad etc all have data there on

this with recommendations.........



Regards,

Chris

-----Original Message-----

From: Leadfree [mailto:[log in to unmask]] On Behalf Of Victor G.

Hernandez

Sent: 17 February 2005 15:07

To: [log in to unmask]

Subject: Re: [LF] RoHS compliance PCB



How can the decomposition temperature of a finish PCB/PWB is determine.

There must be some laminate analysis to extract this value and/or

constituent.



Victor,



-----Original Message-----

From: Leadfree [mailto:[log in to unmask]] On Behalf Of Smith, Rick

Sent: Thursday, February 17, 2005 8:38 AM

To: [log in to unmask]

Subject: Re: [LF] RoHS compliance PCB



Ken,



Check with your process guys. I have found increasing laminate

decomposition temperature to above 330 C is required, and moving to 170

Tg laminate is unnecessary and a cost adder with respect to 4/8 layer

computer boards. 



Laminates with Tg 145, 150 survive LF BGA rework provided the

decomposition temperature is >330 C.



Anyone else working on laminates have input?? Please coment.



thanks



  



-----Original Message-----

From: Leadfree [mailto:[log in to unmask]] On Behalf Of Ken Patel

Sent: Wednesday, February 16, 2005 5:06 PM

To: [log in to unmask]

Subject: [LF] RoHS compliance PCB



All,



I have heard that Fab Houses are moving directly to Halogenfree process,

skipping middle step knowing that Halogenfree is next in line to be

implemented. As our current fabs are built using laminate made of Tg of

170

C or more with Nickel Gold surface finish, do you see any problem?







Do we have to worry besides updating the fab notes asking for RoHS

compliance? We expect fab house to build products based on impedance

requirement. Any comments, suggestion?







Re,



Ken Patel





------------------------------------------------------------------------

-------Leadfee Mail List provided as a service by IPC using LISTSERV

1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send: SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

------------------------------------------------------------------------

-------



------------------------------------------------------------------------

-------Leadfee Mail List provided as a service by IPC using LISTSERV

1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send: SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

------------------------------------------------------------------------

-------



------------------------------------------------------------------------

-------Leadfee Mail List provided as a service by IPC using LISTSERV

1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send: SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

------------------------------------------------------------------------

-------





-----------------------------------------

This message (including any attachments) may contain confidential

information intended for a specific individual and purpose.  If you are not

the intended recipient, delete this message.  If you are not the intended

recipient, disclosing, copying, distributing, or taking any action based on

this message is strictly prohibited.



-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-------------------------------------------------------------------------------

ATOM RSS1 RSS2