Hello together!

The Balver Zinn's recommended lead-free alloy (SN100C) has Ni instead of Ag
and the physical properties are:

Composition:Sn Cu 0,7Ni
Melting point: 227 ºC
Tensile strength (10 mm/min): 32 MPa
Fracture strain: 48 %
Has anybody considered this alloy to change to lead-free instead the most
accepted SAC alloy?
Thank you!
Regards
Jose