Hi Joey and Tom. Just barely- It's o'beer:30 in these parts.
I agree, don't use that particular script without tweaking it as Joey shows.
Dave Corbett suggested that we change to the optional military design. I can't remember where it is drawn at the moment. The electrodes all lay directly on top of each other, and there is no Y (trumpet), but rather a T at each layer. 1-10C committee approved this recommendation in Vegas. The primary benefit is real-estate. It will be added to 2221 appendix A draft.
Have a great weekend.
Chris
-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Thomas E Kemp
Sent: Friday, May 14, 2010 4:36 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] E coupon configuration
Yes, we used to build our coupons like that until DSCC slapped our hands for the reasons mentioned. The IPC-2221 Coupon sub-committee is looking into the feasibility of creating this coupon in this fashion now. Chris, are you out there?
Tom
Jose A Rios <[log in to unmask]>
Sent by: IPC-600-6012 <[log in to unmask]> 05/14/2010 03:24 PM Please respond to "(Combined Forum of D-33a and 7-31a Subcommittees)" <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[IPC-600-6012] E coupon configuration
We noted that our coupon generator flips the direction of the Y circuit
pattern on the 10th layer to control the length of the E coupon, as shown
in the 1st screenshot below.
Arguably it may compromise the integrity of the test between layers 10 and
11, since there is basically no overlapping circuits. Does a re-design
like the one the 2nd screenshot below violate any coupon design reqts??
The 10th plane use wires in both directions so that it is effective in
testing both against the 9th and 11th planes like this. (Blue is the 10th
plane, Yellow is the 11th plane, purple-ish is where there is data on both
planes)
Has anyone else run into this situation??
Joey Rios
PWB & Process Quality Eng'r
Endicott Interconnect Technologies
1093 Clark St.
Endicott, NY 13760
Office: 607-755-5896
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|