Subject: | |
From: | |
Reply To: | (Combined Forum of D-33a and 7-31a Subcommittees) |
Date: | Tue, 25 May 2010 14:30:34 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi Everyone,
The "greater than or equal" symbol in the title to Table 3-3 of IPC-6012C is there by intent. It is there to address the plain vanilla 2-sided printed boards. When we split out the plating thickness tables (used to all be Table 3-2) we picked up greater than 2 layers and all the sub type constructions, but forgot to include plain double-sided boards.
John Perry
Technical Project Manager
IPC - Association Connecting Electronics Industries(r)
3000 Lakeside Drive # 309S
Bannockburn, IL 60015-1249 USA
+1 847-597-2818 (tel)
+1 847-615-7105 (fax)
+1 847-615-7100 (Main)
[log in to unmask]
www.ipc.org
-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Jose A Rios
Sent: Tuesday, May 25, 2010 2:17 PM
To: Listserv IPC-600-6012
Subject: Re: [IPC-600-6012] New rev C
it sure looks that way....
Joey Rios
PWB & Process Quality Eng'r
Endicott Interconnect Technologies
1093 Clark St.
Endicott, NY 13760
Office: 607-755-5896
Wendi Boger <[log in to unmask]>
Sent by: IPC-600-6012 <[log in to unmask]>
05/25/2010 02:35 PM
Please respond to
"(Combined Forum of D-33a and 7-31a Subcommittees)" <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[IPC-600-6012] New rev C
Everyone,
Is there a typo on Table 3-3 in 6012 Rev C? Shouldn't it say > 2
layers not >/= 2 layers. The 2 layers buried via would be covered under
Table 3-5.
Wendi
This communication is for use by the intended recipient(s) only and may
contain information that is privileged, confidential, proprietary and
exempt from disclosure under applicable law. You are hereby notified that
any dissemination, distribution, forwarding or copying hereof is strictly
prohibited without the express written consent of DDi. If you have
received this communication in error or are not the intended recipient,
you should destroy the message and any attachments or copies, and you are
prohibited from retaining, distributing, disclosing, or using any
information contained herein. Please inform us of the erroneous delivery
by return e-mail. Thank you for your cooperation.
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|