remember this monthly full carbon treatment was before the acid copper of
today.

Mike

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]]On Behalf Of Henesian,
Aram
Sent: Monday, June 20, 2005 1:16 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Grain Structure


Pete,
Dr. Engelmaier is right on target.  In the old Lockheed Missiles & Space
Co., we started with plated-through hole PWBs in 1964 and soon carbon
treatment became almost a monthly ritual.

Aram Henesian



-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Werner
Engelmaier
Sent: Monday, June 20, 2005 9:18 AM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] Grain Structure


Hi Pete,
I would drop any PCB fab house that does not carbon treat like a hot
potato.