IPC-600-6012 Archives

May 2007

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Sheila Akins <[log in to unmask]>
Reply To:
(Combined Forum of D-33a and 7-31a Subcommittees)
Date:
Fri, 11 May 2007 09:56:07 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (71 lines)
Hello Constantino,
      Tear drop pads are a default in the world of flex pcbs. Unless there is a tight spacing requirement that might be jeopardized we use this design on all of our product even if it is not in the dynamic (bending) area.  

Best Regards,
Sheila Akins
ISO Management Representative
IPhone: (714) 854-1469
PCell: (714) 222-2602
CFax: (714) 854-1469
8email: [log in to unmask]

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Constantino J. Gonzalez
Sent: Thursday, May 10, 2007 4:39 PM
To: [log in to unmask]
Subject: [IPC-600-6012] FW: Pad to trace interface on BGAs.
Importance: High

Hello, I have a customer with a problem described below, PLEASE HELP?

The problem is that several boards are being returned to the plant after
failing in the field.

 

After Failure Analysis the engineers have found that the reason for the
failure is that one of the traces of the PCB connected to a BGA pad is
becoming cracked (Micro crack at BGA Pad AJ29 in the corner of the BGA) as
showed in picture below:

 

   

 

They have concluded that Copper qty at PCB layer is not enough to support
the normal Mechanical Stress in the unit chassis during the Transportation
resulting in the trace and pad crack.

Based on Jedec JESD22B113 standard, they are suggesting that the customer
change design on the traces connected to BGA pads as shown below: Does the
IPC7351 suggest anything related to this.

 



 

I have not heard before about this type of junction from traces to pads, and
being honest I did not know the Jedec STD mentioned.

 

Have any of you ever heard about this special union from traces to BGA pads
to avoid stress or any other recommendation to reinforce trace to pad
joints?

Could you please enlight me with your thoughts or opinions about this issue?

 

Thanks,

 

 

 Constantino Gonzalez 

ATOM RSS1 RSS2