IPC-600-6012 Archives

December 2008

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Constantino Gonzalez <[log in to unmask]>
Reply To:
(Combined Forum of D-33a and 7-31a Subcommittees)
Date:
Mon, 22 Dec 2008 20:04:11 -0700
Content-Type:
multipart/related
Parts/Attachments:
text/plain (4 kB) , image001.gif (14 kB) , image002.gif (4 kB) , image005.gif (7 kB)
Hello, I have a customer with a problem described below, Could you PLEASE
HELP ME?
The problem is that several boards are being returned to the plant after
failing in the field.
 
After Failure Analysis the engineers have found that the reason for the
failure is that one of the traces of the PCB connected to a BGA pad is
becoming cracked (Micro crack at BGA Pad AJ29 in the corner of the BGA) as
showed in picture below:
 
image001.gif   image002.gif
 
They have concluded that Copper qty at PCB layer is not enough to support
the normal Mechanical Stress in the unit chassis during the Transportation
resulting in the trace and pad crack.
Based on Jedec JESD22B113 standard, they are suggesting that the customer
change design on the traces connected to BGA pads as shown below: Does the
IPC7351 suggest anything related to this…
 
image003.gif
 
I have not heard before about this type of junction from traces to pads, and
being honest I did not know the Jedec STD mentioned.
 
Have any of you ever heard about this special union from traces to BGA pads
to avoid stress or any other recommendation to reinforce trace to pad
joints?
Could you please enlight me with your thoughts or opinions about this issue?
 
Regards.
 
Constantino J. González, ACME, INC. - GALUSAMEX REPAIR Co.
President / Consultant Engineer - Official IPC MASTER INSTRUCTOR - IPC-A-610
Committee Chairman
USA Cell Phone: 605-381-5963 - Mexico Cell Phone: 55-2709 - 6392 -
<mailto:[log in to unmask]> [log in to unmask] or  <mailto:[log in to unmask]>
[log in to unmask] 
  
Does your Company need Rework, Repair or Inspection of Electronic Assemblies
Services. 
Do you have too much Rework, Scrap or Rejects from your Customer…..Call us,
We can help!
GALUSAMEX REPAIR Co.
   


ATOM RSS1 RSS2