unless the design specifically calls out buried caps, we tend to not cap
plate internals.
a generic note like what you cite below "fill, planarize, cap" we tend to
only apply it to externals.
Joey Rios
PWB & Process Quality Eng'r
Endicott Interconnect Technologies
1093 Clark St.
Endicott, NY 13760
Office: 607-755-5896
Chris Mahanna <[log in to unmask]>
Sent by: IPC-600-6012 <[log in to unmask]>
02/09/2011 04:38 PM
Please respond to
"(Combined Forum of D-33a and 7-31a Subcommittees)" <[log in to unmask]>
To
[log in to unmask]
cc
Subject
[IPC-600-6012] buried cap thickness
I assume that we purposely did not include a caveat for buried cap
thickness in 6012C?
My particular interest is the case where the design predates 6012C and
gives no more specifics than: "fill, planarize and cap"
Thanks
Chris
Chris Mahanna
President, Technical Manager
Robisan Laboratory Inc.
6502 E. 21st Street
Indianapolis, Indiana 46219
317-353-6249
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|