IPC-600-6012 Archives

June 2010

IPC-600-6012@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Gary Ferrari <[log in to unmask]>
Reply To:
Date:
Fri, 18 Jun 2010 06:21:57 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (55 lines)
Wendy,

I agree with your assessment. The coupon should be representative of the 
design. the 1-3 via structure sees different stresses than what will be 
shown by separating the structures.

Gary

On 6/17/2010 6:30 PM, Wendi Boger wrote:
>   Need clarification on the definition of Via Structures as is relates to
> Microsection Requirements.
>
>
>
> 3.6.1.5 Microsection Requirements
>
>
>
>              ..... Evaluation of all applicable PTHs and vias, including
> blind and buried, for all such structures found on the finished printed
> board shall be inspected in the vertical cross section in accordance
> with Table 4-3. ...
>
>
>
>   If a board has 1-2 lasers and 1-2-3 stacked lasers is it correct to
> have 2 coupons one as 1-2 and one as 2-3.  Both drill cycles and plating
> cycles are represented but the 1-2-3 total via structure is not.   Seems
> like the 1-2 and 2-3 only is bending the intent.
>
>
>
>
>
> Wendi
>
>
>
>
>
> This communication is for use by the intended recipient(s) only and may contain information that is privileged, confidential, proprietary and exempt from disclosure under applicable law. You are hereby notified that any dissemination, distribution, forwarding or copying hereof is strictly prohibited without the express written consent of DDi. If you have received this communication in error or are not the intended recipient, you should destroy the message and any attachments or copies, and you are prohibited from retaining, distributing, disclosing, or using any information contained herein. Please inform us of the erroneous delivery by return e-mail. Thank you for your cooperation.
>
> ______________________________________________________________________
> This email has been scanned by the MessageLabs Email Security System.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>
>    


______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2