Who says osmosis doesn't work.
Dewey

-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of John Perry
Sent: Tuesday, May 25, 2010 3:09 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] New rev C Table 3-3

Hi Scott and Everyone,

The more I think about this, the more I am wondering how double-sided
printed boards would be excluded if we just went back to "buried vias >
2 layers"?  There is no such thing as a 2 layer buried via in a double
sided printed board, correct?  

John Perry
Technical Project Manager
IPC - Association Connecting Electronics Industries(r)
3000 Lakeside Drive # 309S
Bannockburn, IL 60015-1249 USA 
+1 847-597-2818 (tel)
+1 847-615-7105 (fax)
+1 847-615-7100 (Main)
[log in to unmask]
www.ipc.org



-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Scott
Bowles
Sent: Tuesday, May 25, 2010 4:08 PM
To: Listserv IPC-600-6012
Subject: Re: [IPC-600-6012] New rev C Table 3-3

John,

I understand what the intent was now but I think I did just what Wendi
probably did and that was read it literally as "Buried Vias ( 2 layers".
This is due to the syntax/punctuation of the heading.  I guess something
more along "Table 3-3 Surface and Hole Copper Plating Minimum
Requirements for Through-Holes and Blind Vias ( 2 Layers, and Buried
Vias > 2 Layers1" may have been more appropriate.



Scott A. Bowles
Director of Engineering and Quality
Hallmark Circuits, Inc.
13500 Danielson Street
Poway, CA 92064

858 513-2200 Office x8848
858 513-2233 Fax
858 437-7827 Cell


Notice:  This e-mail is intended solely for use of the individual or
entity to which it is addressed and may contain information that is
proprietary, privileged and exempt from disclosure under applicable law.
If the reader is not the intended recipient or agent responsible for
delivering the message to the intended recipient, you are hereby
notified that any dissemination, distribution or copying of this
communication is strictly prohibited. This communication may also
contain data subject to U.S. export laws. If so, that data subject to
the International Traffic in Arms Regulation cannot be disseminated,
distributed or copied to foreign nationals, residing in the U.S. or
abroad, absent the express prior approval of the U.S. Department of
State. If you have received this communication in error, please notify
the sender by reply e-mail and destroy the e-mail message and any
physical copies made of the communication. Thank you. 


-----Original Message-----
From: John Perry [mailto:[log in to unmask]]
Sent: Tuesday, May 25, 2010 12:31 PM
To: [log in to unmask]
Subject: Re: [IPC-600-6012] New rev C

Hi Everyone,

The "greater than or equal" symbol in the title to Table 3-3 of
IPC-6012C is there by intent.  It is there to address the plain vanilla
2-sided printed boards.  When we split out the plating thickness tables
(used to all be Table 3-2) we picked up greater than 2 layers and all
the sub type constructions, but forgot to include plain double-sided
boards.

John Perry
Technical Project Manager
IPC - Association Connecting Electronics Industries(r)
3000 Lakeside Drive # 309S
Bannockburn, IL 60015-1249 USA
+1 847-597-2818 (tel)
+1 847-615-7105 (fax)
+1 847-615-7100 (Main)
[log in to unmask]
www.ipc.org



-----Original Message-----
From: IPC-600-6012 [mailto:[log in to unmask]] On Behalf Of Jose A
Rios
Sent: Tuesday, May 25, 2010 2:17 PM
To: Listserv IPC-600-6012
Subject: Re: [IPC-600-6012] New rev C

it sure looks that way....

Joey Rios
PWB & Process Quality Eng'r
Endicott Interconnect Technologies
1093 Clark St.
Endicott, NY 13760
Office: 607-755-5896



Wendi Boger <[log in to unmask]>
Sent by: IPC-600-6012 <[log in to unmask]>
05/25/2010 02:35 PM
Please respond to
"(Combined Forum of D-33a and 7-31a Subcommittees)"
<[log in to unmask]>


To
[log in to unmask]
cc

Subject
[IPC-600-6012] New rev C






Everyone,



    Is there a typo on Table 3-3 in 6012 Rev C?  Shouldn't it say > 2
layers not >/= 2 layers.  The 2 layers buried via would be covered under
Table 3-5.



Wendi



This communication is for use by the intended recipient(s) only and may
contain information that is privileged, confidential, proprietary and
exempt from disclosure under applicable law. You are hereby notified
that
any dissemination, distribution, forwarding or copying hereof is
strictly
prohibited without the express written consent of DDi. If you have
received this communication in error or are not the intended recipient,
you should destroy the message and any attachments or copies, and you
are
prohibited from retaining, distributing, disclosing, or using any
information contained herein. Please inform us of the erroneous delivery
by return e-mail. Thank you for your cooperation.

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________



______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask]
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or
[log in to unmask] 
______________________________________________________________________

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2