Thanks Jack,
I'll let you know what we find.

In the mean time if anyone here has additional info, it would be
appreciated.

Eric Bonatti, C.I.D.
EDA Group Leader
Phone: +1 905 812 6200 xt.3412
Fax: +1 905 812 6301
E-mail: [log in to unmask]
 
Psion Teklogix Inc.
2100 Meadowvale Boulevard, 
Mississauga, ON, L5N 7J9, Canada
 

-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of Jack
Olson
Sent: Fri. 08 June 2007 14:27
To: [log in to unmask]
Subject: Re: [DC] Gold plating question / IPC spec?

There's a spec for Gold Plating, IPC-4552

I don't think it relates thickness to cycles.
and I'm pretty sure its because the studies
that were done "way back when" showed
that as long as the process was controlled,
you would get more cycles than you would
ever need.
I think it was Bell Labs that wanted to start
gold plating contacts on phones, and after
a million or so cycles they couldn't see
ANY damage, and abandoned the rest of
the test. (That's the way I heard it, anyway)

The point was, its NOT a situation like "if you
double the gold you get twice as many cycles".
It doesn't work that way....

Let us know if you hear differently, ok?

Jack



On 6/8/07, Eric Bonatti <[log in to unmask]> wrote:
>
> Hello group,
> I have a question regarding the gold plating specs for some contacts.
>
> Is there an IPC spec that relates the thickness of gold plating to the
> number of cycles that the plated contact can withstand?  (i.e. for an
> edge connector card or the contacts on a rechargeable battery that is
> taken out and re-installed in the unit a few times daily)
>
> Thanks in advance for your time.
>
> Eric Bonatti, C.I.D.
> EDA Group Leader
> Phone: +1 905 812 6200 xt.3412
> Fax: +1 905 812 6301
> E-mail: [log in to unmask]
>
> Psion Teklogix Inc.
> 2100 Meadowvale Boulevard,
> Mississauga, ON, L5N 7J9, Canada
>
>
>

------------------------------------------------------------------------
---------
DesignerCouncil Mail List provided as a free service by IPC using
LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET
DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases
> E-mail Archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
------------------------------------------------------------------------
---------

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2