DESIGNERCOUNCIL Archives

December 2004

DesignerCouncil@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Roger Stoops <[log in to unmask]>
Reply To:
(Designers Council Forum)
Date:
Fri, 10 Dec 2004 16:32:49 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (40 lines)
No, it isn't a good practice, but how many times has a designer/detailer/engineer had to put 3 details and 14 notes on an assembly drawing to show how they want the connector to be assembled?  Document what you design, and keep notes on what took place; maybe someone will see the need to change company/individual practice.  Extensive docs are not the best solution, but sometimes that's all we can do until the climate changes and the wind blows another direction.

About 2-3 years ago, or maybe more, Framitome (who bought out Berg) renumbered their Minitek(tm) 2mm line of connectors to match standard 2-row IDC pinout.  THAT was fun!?!  Had to add notes/details to all the affected drawings.  And the mating housings we had in stock had the wrong pin 1 indicator for a time.  Our documentation was detailed enough to avert potential problems.

This has been a stimulating discussion.  Everybody have a good weekend, and for those in the northern hemisphere, keep warm!
Humble Regards,

Roger


-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]]On Behalf Of Ted
Tontis
Sent: Friday, December 10, 2004 4:16 PM
To: [log in to unmask]
Subject: Re: [DC] Din connectors


        I don't think it is a question about who can change the pin outs of a connector when they see fit. The question is if it is a good practice to do so. As a PCB designer it is the designers responsibility to design a board that exactly represents what is to be built and assembled. If I send a design out that has the silkscreen mirrored and they put the connector in wrong who's fault is it? They built the design as I told them too, or as the data states. What is correct the pin out or the silkscreen?
I know the assembly house should call when a red flag is tripped but how many do, and who is to say they are going to get the same engineer or designer who knows what is going on with this design?
This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the system manager. This message may contain confidential information and is intended only for the individual named. If you are not the named addressee you should not disseminate, distribute or copy this e-mail.

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2