Agree that its low producibility, however, some industry capability does exist for drilling and metallization of a 6 mil hole on a 62 mil pad with external annular ring exceeding tangency.

Joey Rios
MIT Kavli Institute
Cambridge, MA

Sent from my iPhone

> On Feb 18, 2016, at 7:48 PM, Mathis, Louis (SSA R4) <[log in to unmask]> wrote:
> 
> A 6 mil drill in a 12 mil pad will not meet the design requirements in IPC-2221, paragraph 9.1.1.  Even using the Level C fabrication allowance, the minimum pad would be .0179 plus the tolerance of the drill diameter.
> 
> -- 
> Louis Mathis 
> Member of the Technical Staff
> Cobham Microelectronic Solutions
> T : +1 858-505-3151
> 
> Please consider the environment before printing this email
> 
> 
> -----Original Message-----
> From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of Ron Olinyk
> Sent: Thursday, February 18, 2016 3:56 PM
> To: [log in to unmask]
> Subject: [DC] Mechanical drill -6mil aspect ratio
> 
> ** Please note that the Sender of this email is from outside the Cobham NA IT Hub **
> 
> Does anyone know what the typical aspect ratio would be for a 6mil
> (0.152mm) drill in FR4 would be?
> Can a 6mil drill be used as a full drill-thru on 0.062 thick circuit board? -which I think would be a 10:1 aspect ratio...
> 
> I've got a design with a 0.5mm uBGA (169 pin, full array) that i want to do fanout vias between pads.  I'm using a 8.7mil BGA pad and planning on a fanout via with a 12mil pad and 6mil drill.  I originally set this up as a blind via from top to inner1 layer, which works, but I am quickly running out of available via room around the BGA for connecting signals, power/gnd, ect.  I'm using an 8mil drill elsewhere on the board which I know is doable on a 0.062 board -just not sure if 6mil is doable -and with a 3mil annular ring!
> 
> Any advice greatly appreciated.
> Thanks
> Ron
> 
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
> 
> ---------------------------------------------------------------------------------
> DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
> To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
> To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL) For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> ---------------------------------------------------------------------------------
> 
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask] 
> ______________________________________________________________________
> 
> ---------------------------------------------------------------------------------
> DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
> To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
> For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
> ---------------------------------------------------------------------------------

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 16.0.
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
For additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2