Eric,
I have been putting vias at .014 min to SMT pads for 2 years.
QC hasn't had any problems or issues with it. This is typical
for all types of SMT parts. We choose .014 because it works out
well with our pad sizes and a .005 grid. We used .015 for 3
years prior to going to .014.
The other consideration is your soldermask clearance pad
sizes. You don't want to end up with a soldermask web that is
to small or you will get flaking.
Brandon Luther
Dataram Corp.
______________________________ Reply Separator _________________________________
Subject: Via to Smt Pads
Author: [log in to unmask] at Internet
Date: 3/7/97 10:17 AM
To all PCB Design Conqueror's,
I have a situation arising in our manufacturing facility. We are finally
graduating
to bottom side SMT design. I am butting heads with the IE (Industrial Eng.)
Dept. on
how close we can place via's to bottom side pads for caps and resistor's.
Currently
we have a horizontal flow with vertical placement of parts running through the
wave.
I started routing boards with a clearance of .015" in any given direction from
the
bottom side pads. My IE Dept. wants a minimum of .025" in any direction, without
having
any source to base this on. Does anyone have a standard that they use or is
there a
spec that states how far from a bottom side pad a via should be?
Thanks.
Eric Lucik
[log in to unmask]
***************************************************************************
* The mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text.*
***************************************************************************
* If you are having a problem with the DesignerCouncil, please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* The mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text.*
***************************************************************************
* If you are having a problem with the DesignerCouncil, please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|