Mitch Morey wrote:
>
> Help.
>
> How do I call out 1/2oz Copper per MIL-P-13949? I know it's C1/C1 for 1oz
> over 1 oz. What's 1/2?
>
> Thanks,
>
> Mitch Morey
Mitch,
this is how we specify our copper:
------------------------------------------------------
Laminate shall be in accordance with MIL-S-13949/H.
Copper weight is 1 oz./sq. ft. internal and 1/2 oz./sq. ft.
external. Final composite thickness will be .062" +/- .004".
Typical material specification, as per ANSI/IPC-D-275,
is Type GFN-0620-CH/CH-B1B where:
GFN = FR4 glass fabric impregnated with flame retardant epoxy resin
0620 = nominal dielectric base thickness (ten-thousandths of an inch)
CH = top side, metallic foil type and nominal weight (ounce/sq. ft.)
CH = bottom side, metallic foil type and nominal weight (ounce/sq.ft.)
B = laminate quality (pits and dents per sq. in.)
1 = thickness tolerance
B = laminate material bow and twist
------------------------------------------------------
I hope this helps.
Ciao!
Eric Bonatti
PCB Design
GN Nettest, Datacom division