wow, NO responses yet?

I've read that paragraph three times now,
and I'm still not sure what the problem is.

It sounds like they are trying to maintain your 1mil annular ring
requirement,
and are working on a design with 4mil minimum clearances, but is it the fact

that you need plugged blind vias what is causing the difficulty?
Sorry I can't help, but I'm curious.

I don't suppose IPC has a "HOTLINE" you can call to clarify requirements?
HA.

good luck,
Jack


On 4/10/07, Mitch S. Morey <[log in to unmask]> wrote:
>
> Hi all,
>
> I recently had this response from my fabrication house, and was wondering
> if anyone else has run into this issue. I'm still trying to figure out
> exactly what it means (e.g. costs me).
>
> ----------------------------
> Due to blind vias/epoxy fill requirement & spacing on the outer layers, a
> new copper wrap plating process cannot be achieved per IPC 6012B due to
> spacing issues. I would like to verify if we can wave this process since
> you have less than 4 mils space on your data. Please see below.
>
> In mid January of 2007, IPC released Amendment 1 of 6012B, updating it's
> copper wrap plating spec (3.6.2.11.1) that reads as follows:
>
> Copper wrap plating minimum as specified in Table 3-2 shall be continuous
> from the filled plated hole onto the external surface of any plated
> structure and extend by a minimum of 25 um (984uin) where an annular ring
> is required.  Reduction of wrap-plating by processing (sanding, etching,
> planerization, etc.) resulting in insufficient wrap plating is not
> allowed.
> XXX1 is committed to manufacturing your PCB's to the highest standards.
> Due to the panelizing process, designs requiring a space of 4 mils or
> smaller can not be built to this spec.
> ----------------------------
>
> Thanks in advance.
> Mitch
>
>
>
>

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2