Have you contacted the customer and asked if there was a specific reason for
this requirement? Maybe if can address their concerns they maybe more
inclined to be less stringent. I designed a four layer board once that had
power and ground planes on the outer layers and signal traces in the inner
layers. It actually turned out to be very easy to route, this maybe an
option.
Regards,
Ted T.
-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of wheels
Sent: Wednesday, March 18, 2009 9:44 AM
To: [log in to unmask]
Subject: [DC] Traces and vias under components
Guys,
We have a customer which we are designing a mostly SMT board for that
requires all traces and vias not to be under components. This would also
include any planes being under the components. I guess in the past they had
a board designed by some else that had a shorting problem with traced and
vias under the components. They are insistence that this is the way it has
to
be. Has anyone else had experience with this sort of demands? This is not
for
space, military, high voltage, high vibration or a medical application. Can
anyone think of anything we could tell they to change their mind?
Thank you,
wheels
----------------------------------------------------------------------------
-----
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET
DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
----------------------------------------------------------------------------
-----
----------------------------------------------------------------------------
-----
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET
DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------
|
|
|