We are required to run the Hygroscopic Dust Test (part of NEBS testing).
The test is performed to simulate 30 years of environmental exposure.
The hygroscopic dust is applied as a liquid spray and is then dried for
24 hours. After the liquid is dried the board is powered up at humidity
levels between 70% and 80% and is required to be 100% operational.
Sensitive circuitry could fail due to low impedances paths created at
high humidity. In fact I have seen an intermittent failure on some of
the more sensitive clock circuitry during these tests. 
 
I need to specify a sealant to apply around the BGA devices with
sensitive circuitry. This bead of sealant around the BGA should prevent
the liquid spray from entering the pin field under the BGA. I know that
conformal coating the entire board is out of the question here so please
only suggest solutions that seal around a specific BGA device. Does
anyone have a recommendation on the type of sealant that should be used
or you have used in the past? Obviously, I will be calling my CM to
discuss this issue but I wanted some feedback from the forum also. 
 
Thanks
Tony  Cosentino
Tekelec
[log in to unmask]
919-460-3656

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------

ATOM RSS1 RSS2