Back in 1995 at a different company, I worked on a multilayer RF
amplifier board that mounted on an aluminum surface. We used a different
drill code (+1mil) for the non ground vias and specified that drill code
in the NC drill file as the locator for the controlled depth drilling.
Since that time I've heard the product has performed well in the field
with no problems. Can't remember where we got it fabricated but I
remember calling several vendors to find one with that capability. Just
a thought on the pad removal. You may need the bottom pad for the via
hole plating process. Just use a small pad on the bottom layer and let
them drill it out.

Best Regards,
Gary Shoemaker, C.I.D.
Senior PCB Designer

Cisco Systems, Inc.
3875 Embassy Parkway
Akron, Ohio 44334

Phone: 330-664-7927
Fax: 330-664-7301

---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To set a vacation stop for delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2