Assuming your transmission lines are on the external layers, the only
place you *really* need a tighter tolerance is between the external
layer and its reference plane layer. This should be unaffected by an
overall 10% tolerance. The overall thickness tolerance allows the
fabricator some leeway with the variables of lamination.
Denis Lefebvre, CID+
Sr. PCB Designer
Finisar Corporation
(408)542-3832
-----Original Message-----
From: DesignerCouncil [mailto:[log in to unmask]] On Behalf Of
Babcock John
Sent: Tuesday, June 26, 2007 8:21 AM
To: [log in to unmask]
Subject: [DC] Board Thickness Tolerance
Fellow Designers,
Long time lurker, first time poster. I've had a few posts over the
years, just not very many.
Ok here goes.
What is a good overall thickness tolerance to put on your dwg for a
0.125" thick board? This board is impedance controlled and should stay
pretty close to the 0.125" to meet our required impedance values.
I am kind of in a unique situation where we deal directly with an
assembly house and that assembly house farms out the board fab to
whoever gives them the best quote. So I never know which board house
will get the board. Hence I never know the capabilities of the board
house where the board gets sent to be made.
With that being said, XYZ board house wants to loosen up the tolerance
to +/- 0.012" on the overall board thickness. This would throw our
impedance calculations off.
Just kind of curious what everyone would expect as a good tolerance on a
0.125" board.
John Babcock, C.I.D.
PCB Designer III
------------------------------------------------------------------------
---------
DesignerCouncil Mail List provided as a free service by IPC using
LISTSERV 1.8d To unsubscribe, send a message to [log in to unmask] with
following text in the BODY (NOT the subject field): SIGNOFF
DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET
DesignerCouncil NOMAIL/(MAIL) Search previous postings at: www.ipc.org >
On-Line Resources & Databases > E-mail Archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
------------------------------------------------------------------------
---------
---------------------------------------------------------------------------------
DesignerCouncil Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF DesignerCouncil.
To temporarily stop/(restart) delivery of DesignerCouncil send: SET DesignerCouncil NOMAIL/(MAIL)
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
---------------------------------------------------------------------------------
|
|
|